342 Chapter 8 Removal & Installation
Removal & Installation
17. Move the Carriage Assembly slightly away from the
right Scan-Axis Bracket.
18 . Release the Carriage Belt from the Scan-Axis Motor on
the left hand side of the Printer.
19. Remove one T-10 screw (Type C) that secure the
Encoder Strip.
20.Remove four T-20 screws (Type N) that secure the right
Scan-Axis Bracket.
NOTE: Note that these are Chassis screws
and in normal circumstances should NEVER be
removed, but in this case we need to remove
them in order to remove the Carriage Assembly.