9. The printer now aligns the printheads. When the following message appears, press OK to
continue or Cancel to exit.
10. When the printhead alignment is completed, the following message is be displayed. Press OK to
continue.
If the printhead alignment fails for any reason, a warning message will appear on the front panel.
In this case, try the following:
●
Enter the front panel menu and retry the printhead alignment.
●
If the printhead alignment fails again, check the alignment pattern to see whether any of the
printheads are printing incorrectly. If necessary, perform a printhead recovery through the
front panel and retry the printhead alignment.
11. When the whole Line Sensor calibration is completed successfully, the following message is
displayed.
Calibrate Rewinder
The purpose of this Service Calibration is to calibrate the printer's Rewinder Motor parameters.
1. Load an empty spindle into the printer.
2. Select Calibrate Rewinder from the Calibrations menu.
3. Press OK to continue, then there is a short delay while the calibration is performed.
134 Chapter 5 Service calibrations ENWW
Service calibrations