NOTE: After installing the NEW Service Station, make sure you perform the following Service
Utility:
●
Reset Counter PHC spittoon
Reset Life Counters on page 108.
NOTE: After installing the NEW Service Station, make sure you perform the following
Service Calibration:
●
Drop Detector calibration
Drop Detector calibration on page 129.
Removal of the Service Station Scraper
1. Release the clip securing the Scraper to the Service Station.
2. Remove the Scraper from the Service Station.
256 Chapter 8 Removal and installation ENWW