HP ProLiant DL360 G3 Server High-Density Deployment
Preliminary
18
Power
Configurations
Examples
The high/low voltage and dual-power supply capabilities of the ProLiant DL360 G3
server makes it adaptable to a variety of power configurations. Each of the following
examples suggests a method of power distribution for a group of servers mounted in a
rack. These examples illustrate server power configurations only as well as ways to
accomplish server management using iLO and KVM switching products and do not take
into account such accessories as KVM switches and display monitors that are typically
included in an installation.
Suggested
Configurations
Table 6 is a Quick Reference table with suggested rack configurations for deploying
ProLiant DL360 G3 servers. Examples of these configurations are further explained later
in this section in Configurations A, B, and C.
Table 6. Suggested Rack Configurations Quick Reference
Configuration A B C
Priority
Maximum Performance
Density
Redundant Power
Traditionalist
Rack Size
42U 42U 42U
Server Count
42 35 24
Power Source
High Voltage High Voltage Low Voltage
PDU
4 x 40 Amp Modular
PDU
4 x 40 Amp PDU 4 x 24 Amp PDU
KVM Switching
No local KVM
Switching
(iLO only)
IP Console Switch IP Console Switch
Local Console
No Local Console TFT5600RKM TFT5600 RKM
Lights-Out
Management
iLO Advanced iLO Advanced
iLO Standard or
iLO Advanced
IP Connections
1 x 48 Port 10/100
Ethernet Switch
(44+4)* for iLO
6 x 16 Port Gigabit
Ethernet Switch for data
2 x 24 Port 10/100
Ethernet Switch
(22+2)** for iLO
1 x 48 Port Gigabit
Ethernet Switch (44+4)*
for data
2 x 24 Port
10/100 Ethernet
Hub for iLO
2 x 48 Port
Gigabit Ethernet
Switch (44+4)*
for data
* 44 10/100 ports plus 4 Gigabit uplink ports