2. If you did an offline upgrade, perform the following steps:
a. Restart any host servers that were shut down for the upgrade.
b. Resume host I/O.
3. When running HP P6000 Continuous Access, set the Failsafe on unavailable member mode
to Enabled on all DR groups if it was disabled before the upgrade. For instructions, see
“Preparing the HP P6000 Continuous Access environment for an upgrade” (page 36).
4. If you changed any host LUN timeout values, reset them to their original values.
5. If you are running Remote Support software, enable it as follows:
a. Save and then clear the application event log file.
b. On the management server, open a command window.
c. Enter the following command to restart Remote Support software:
C:\>net start desta_service
d. Enter exit.
6. Update the MIB file after the upgrade to ensure that SNMP notifications are captured correctly.
See “Retrieving the Management Information Base in the HP P6000 Command View User
Guide for instructions.
Step 8. Resuming array operation 63

Table of Contents

Other manuals for HP EVA P6000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP EVA P6000 and is the answer not in the manual?

HP EVA P6000 Specifications

General IconGeneral
ModelHP EVA P6000
Number of Storage Controllers2
Management SoftwareHP Command View EVA
Drive TypesSAS, SSD
RAID LevelsRAID 0, 1, 5, 6
Connectivity8 Gb Fibre Channel, 10 Gb iSCSI, 1 Gb iSCSI
Form FactorRack-mounted
Storage Controller TypeDual controllers

Related product manuals