QuickSpecs
HPE Integrity Superdome X
Ordering and Configuration
Page 23
command line interface (CLI) are supported on the OA to manage partitions.
The
HPE Superdome X can utilize "ParSpecs" which are a way to save, create, and build partitions from
resource definitions. ParSpec definitions allow yo
u to have overlapping resources as long as the partitions
booted don't all claim the same resources at the same time. One way to use ParSpecs is to create one set for
"end of month" jobs, and another set for "daily work". ParSpec commands are built into th
e OA CLI at first
release.
Step 1: Choose Required Superdome X Enclosure and Power Requirements
Enclosure
HPE Superdome X Base Enclosure
AT147B
HP Superdome X Base Enclosure
AT147A
NOTE: Adding Option code "#0D1" to the enclosure will integrate the enclosure into
the Superdome Rack (which must be on the same order)
NOTE:
Min 1/Max 1 Power Option #001 - #006, #010 must be selected.
Option #007
- can be added if power is out of the top of the rack
NOTE:
Min 1/Max 1 Superdome X partitioning LTU is required for each enclosure
ordered. See HPE Superdome X system software listed below.
Power options
HPE Superdome X Local Power
#001
HPE Superdome X 4 Wire No PDU
#002
HPE Superdome X 5 Wire Intl No PDU
#003
HPE Superdome X 4 Wire 3 Phase PDU
#004
HPE Superdome X 5 Wire Intl 3 Phase PDU
#005
HPE Superdome X 3 Wire Local SP PDU
#006
HPE Superdome X Top Power
#007
HPE Superdome X 3 Wire Japan SP PDU
#010
Enclosure upgrade
HPE Superdome X Crossbar Fabric 2 Module
H7B49A
NOTE: The HPE Superdome X Crossbar Fabric 2 Module can be used to upgrade the
AT147A enclosure to the AT147B enclosure. The upgrade is not required but may
provide up to 33% greater bandwidth for some high
-end configurations
Step 2: Choose Interconnect Module Options
NOTE: Select minimum one (1) and maximum eight (8)
Networking modules
NOTE: Select minimum one (1) and maximum eight (8) networking modules
NOTE:
If the HPE BLc 10GbE pass-thru module (538113-B21) is installed in slots 1 or
2 of the enclosure, the
n the HPE FlexFabric 10Gb 2P 534FLB adapter (700741-B21)
cannot be installed in any blade.
HP 10GbE Ethernet Pass-Thru Module for c-Class BladeSystem
538113-B21
HP 6127XLG Ethernet Blade Switch
787635-B21
HP 6125XLG Ethernet Blade Switch
711307-B21
HP 6125G Ethernet Blade Switch
658247-B21
HP Cisco B22HP Fabric Extender for BladeSystem c-Class
641146-B21
NOTE: Not available factory integrated in bays 1 & 2; can be factory integrated in bays
3-8
HP Cisco B22HP Fabric Extender with 16 FET for BladeSystem c-Class
657787-B21