Paper-pickup assembly
1. Remove the following assemblies.
● Right-side cover. See
Right-side cover on page 64.
●
Left-side cover. See
Left-side cover on page 66.
●
Top-cover assembly. See
Rear panel and top-cover assembly on page 66.
● Transfer roller. See
Transfer-roller assembly on page 73.
● Fuser (fixing) assembly. See
Fuser (fixing) assembly on page 77.
2. Disconnect and unwind any additional wires as necessary to release the paper-pickup
assembly. Unplug and unwind the wire from the solenoid to the formatter.
Disconnect and unwind any additional wires as necessary to release the paper-pickup
assembly. Unplug and unwind the wire from the solenoid to the formatter.
CAUTION Do not pull directly on the wires when a connector is disconnected. Always
pull on the plastic body of a connector to avoid damaging the connector wires.
3. Remove six screws (callout 1), and then remove the paper-pickup assembly.
1
Figure 5-27 Remove the paper-pickup assembly
Reinstallation tip When replacing the paper-pickup assembly, be sure to transfer the
sensor PCB and, if necessary, the separation-pad assembly to the new paper-pickup
assembly.
ENWW Internal assemblies 79
Download Service Manual And Resetter Printer at http://printer1.blogspot.com