10. Slightly rotate the high-voltage power supply down and then pull it straight out of the device. Make
sure that you do not damage the loop sensor flag when you remove the high-voltage power supply.
Tip Make sure that the high-voltage springs on the MFP chassis do not get folded over or
damaged when you reinstall the power supply.
Figure 5-266 Remove the high-voltage power supply assembly (8 of 9)
ENWW Print engine (base unit) 351