Motor(s) and PCA(s)
NOTE The single tray HCI contains one motor and one PCA. The multi tray HCI contains three
motors and three PCAs.
1. Remove the HCI back cover. See Back cover on page 376.
2. Remove two screws (callout 1) and disconnect one connector (callout 2). Remove the HCI motor
(callout 3). Repeat this step for the remaining motors.
3
2
1
Figure 5-305 Remove the HCI motor(s) and PCA(s) (1 of 2)
3. Disconnect six connectors (callout 4) and remove two screws (callout 5). Use a pair of pliers to
release the PCA standoffs (callout 6) and then remove the HCI PCA (callout 7). Repeat this step
for the remaining PCAs.
6
5
7
4
Figure 5-306 Remove the HCI motor(s) and PCA(s) (2 of 2)
ENWW High capacity input feeder 377