Table 3-29 General Settings menu (continued)
First level Second level Third level Fourth level Values Description
Uniformity Control Normal*
Alternate 1
Alternate 2
Alternate 3
This setting might
help correct
uniformity in print
quality issues, such as
a mottled appearance
due to poor transfer
of toner onto the
page. The Alternate 1
setting increases the
T1 transfer bias and
can be used for any
media type. The
Alternate 2 setting
decreases the fuser
temperature and
reduces the
throughput. Use this
setting if you are
experiencing mottled
output due to poor
fusing on normal or
light paper types. The
Alternate 3 setting
applies the Alternate 1
setting and the
Alternate 2 setting at
the same time. Use
this setting if the first
two settings do not
correct the problem.
Tracking Control On*
Off
Normally, this setting
should be set to On.
Tracking control
algorithm is turned
ON/OFF. It is not
expected that the
customer will ever
need to change this
setting.
Registration Normal*
Alternate
Use this setting if you
are having trouble
with color-planes
shifting or overlapping
on the page. Use the
Alternate setting if
you are seeing color
mis-registration
problems.