Display Settings menu
To display: At the product control panel, select the Administration menu, and then select the Display
Settings menu.
In the following table, asterisks (*) indicate the factory default setting.
Table 3-32 Display Settings menu
First level Second level Values Description
Display Brightness Range: -10 to 10
Default = 0
Sets the brightness of the control
panel display. The default is 0. This
item also controls the viewing
angle at which the display is
visible.
Language Select from a list of languages that
the product supports.
Sets the language. The default
language is English.
Show IP address Display*
Hide
Use this feature to display or hide
the IP address on the control-
panel display.
Inactivity Timeout Range: 10 – 300 seconds
Default = 60
Idle Timeout: The time period, in
seconds, after which an idle TCP
print data connection is closed
(default is 60 seconds, 0 disables
the timeout).
Clearable Warnings On
Job*
Sets whether a warning is cleared
on the control panel or when
another job is sent.
Job: The warning message
disappears at the end of the job.
On: The warning message remains
until you press the OK button.
Continuable Events Auto-continue (10 seconds)*
Touch OK to continue
Determines product behavior when
the system generates an Auto
Continuable error.
On: Allows the product to continue
printing.
Off: Stops the product from
printing until the error is cleared
by the user.
ENWW Tools for troubleshooting 365