EasyManuals Logo

HP MSR1002-4 User Manual

HP MSR1002-4
471 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #203 background imageLoading...
Page #203 background image
192
v2c: Specifies SNMPv2c.
v3: Specifies SNMPv3.
Usage guidelines
SNMPv1 and SNMPv2c settings in this command are not supported in FIPS mode.
Configure the SNMP agent with the same SNMP version as the NMS for successful communications
between them.
Examples
# Enable SNMPv3.
<Sysname> system-view
[Sysname] snmp-agent sys-info version v3
Related commands
display snmp-agent sys-info
snmp-agent target-host
Use snmp-agent target-host to configure the SNMP agent to send SNMP notifications (informs or traps)
to a host.
Use undo snmp-agent target-host to remove an SNMP notification target host.
Syntax
Non-FIPS mode:
snmp-agent target-host inform address udp-domain { ip-address | ipv6 ipv6-address } [ udp-port
port-number ] [ vpn-instance vpn-instance-name ] params securityname security-string { v2c | v3
[ authentication | privacy ] }
snmp-agent target-host trap address udp-domain { ip-address | ipv6 ipv6-address } [ udp-port
port-number ] [ vpn-instance vpn-instance-name ] params securityname security-string [ v1 | v2c | v3
[ authentication | privacy ] ]
undo snmp-agent target-host { trap | inform } address udp-domain { ip-address | ipv6 ipv6-address }
par
ams sec
urityname security-string [ vpn-instance vpn-instance-name ]
FIPS mode:
snmp-agent target-host inform address udp-domain { ip-address | ipv6 ipv6-address } [ udp-port
port-number ] [ vpn-instance vpn-instance-name ] params securityname security-string v3
{ authentication | privacy }
snmp-agent target-host trap address udp-domain { ip-address | ipv6 ipv6-address } [ udp-port
port-number ] [ vpn-instance vpn-instance-name ] params securityname security-string v3
{ authentication | privacy }
undo snmp-agent target-host { trap | inform } address udp-domain { ip-address | ipv6 ip
v6-address }
par
ams securityname security-string [ vpn-instance vpn-instance-name ]
Default
No SNMP notification target host is configured.
Views
System view

Table of Contents

Other manuals for HP MSR1002-4

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP MSR1002-4 and is the answer not in the manual?

HP MSR1002-4 Specifications

General IconGeneral
ModelMSR1002-4
Product SeriesMSR1000
Total Ports4
VPN SupportYes
FirewallYes
WirelessNo
Input Voltage100-240V AC
Power Consumption30W
Port TypeEthernet
Ports4 x 10/100/1000Base-T
Additional Ports1 x Console
Power SupplyInternal
Operating Temperature0°C to 45°C

Related product manuals