Event Messages
HP NonStop TMF Management Programming Manual—540140-008
6-27
Descriptions of Event Messages
79: ZTMF-EVT-TmpSendAuditError
TMF tried to write audit information to the specified active-audit volume, but could not
because a file-system error occurred.
Additional Unconditional Tokens
ZTMF-TKN-EVTHDR-ProcessType
identifies the TMF process that generated the event. For this event, the value of
this token is ZTMF-VAL-PROC-TMP.
ZTMF-TKN-VolumeName
is the subject token of the event message, and it contains the name of the active-
audit volume TMF was trying to write to.
ZTMF-TKN-Fs-Error
contains an integer identifying the file-system error that occurred.
ZEMS-TKN-Emphasis
is set to True for this event.
Effect
TMF crashes.
Additional Unconditional Tokens
ZTMF-TKN-EVTHDR-ProcessType token-type ZSPI-TYP-Enum.
ZTMF-TKN-VolumeName token-type ZSPI-TYP-String.
ZTMF-TKN-Fs-Error token-type ZSPI-TYP-Int.
ZEMS-TKN-Emphasis token-type ZSPI-TYP-Boolean.
Event-Message Text
TMP encountered error ZTMF-TKN-Fs-Error attempting to send
audit to the ADP ZTMF-TKN-VolumeName. Crashing TMF.