Error and Warning Messages
HP NonStop TMF Management Programming Manual540140-008
7-68
Dump/Restore Errors and Warnings
9012 The tape has the wrong Archive tape version (Expected version
name: ZTMF-TKN-DR-EXPECTEDTAPEVERNAME, actual version
name: ZTMF-TKN-DR-ARCHTAPEVERNAME).
The tape mounted for a dump restore operation had the wrong archive tape
version.
The ZEMS-TKN-EMPHASIS token is set to TRUE.
9013 Parity error occurred on a tape data block.
A parity error occurred in a tape data block.
The ZEMS-TKN-EMPHASIS token is set to TRUE.
9014 Checksum error occurred on a tape data block.
The checksum of a tape data block was invalid.
The ZEMS-TKN-EMPHASIS token is set to TRUE.
9015 The file was aborted in the middle of the tape dump; it should not be
in the TMF Catalog.
A file cancellation record was found during a dump restore operation, indicating
the dump of the file was aborted in the middle. This could have been caused by
an erroneous ADD DUMPS command.
The ZEMS-TKN-EMPHASIS token is set to TRUE.
9016 The TMF tape format version is not understood by this RVU of
TMF Dump/Restore.
The tape was made with an RVU of the dump process that is incompatible with
the RVU of the restore process used to read it.
The ZEMS-TKN-EMPHASIS token is set to TRUE.
9017 The TMF dump kind is incorrect (Expected kind: ZTMF-TKN-DR-
EXPECTEDDUMPKIND, actual kind: ZTMF-TKN-DR-DUMPKIND). The
TMF Catalog has incorrect information.
A tape specified by the TMF catalog contained the wrong type of dump. This
could have been caused by an erroneous ADD DUMPS command.
The ZEMS-TKN-EMPHASIS token is set to TRUE.