17
Before repairing connectors, follow these steps:
Prepare the monitor for disassembly. See Preparation for disassembly on page 12.
IMPORTANT:
Repair Condition: Connector repair is only for out of warranty.
Repairing must operate by professional repairers (Note) in repair center, not applicable for end user.
Electrostatic protection is required when component replacement is required.
The monitor meets ROHS, please use Lead-free solder wire for soldering.
If Connector need to replace, must check specification and part number whether match the BOM and
location.
If connector need to replace, please insert new parts carefully because the near pin may cause short
circuit by inappropriate operate.
DO NOT allow any liquid on the board. Water and moisture may cause short-circuit to the electronic
components and lead to malfunctions.
The fusion point of Lead-Free solder is requested. Repairing with conventional lead wire may cause
damage.
Work quickly to avoid overheating the circuit board as soon as you confirm the steady soldering condition.
Keep the soldering iron tip clean and well tinned and when replacing parts.
A close inspection of the circuit board revealed look in good condition.