Software Fixes
Release G.05.03
Release G.05.03
Never released.
Crash (PR_4621) — The switch may crash with a message similar to:
-> NMI occurred: IP=0x00317d9c MSR:0x0000b000 LR:0x00013b88 Task='eDrvPollRx' Task
ID=0x1708f20 cr: 0x22000080 sp:0x01708e60 xer.
Release G.05.02 4/19/02
(PR_4944) Continuous Module Reset The J4893A ProCurve Switch GL mini-GBIC
module will go into a continual reset loop when both of the following conditions are met:
1. the module is inserted in slot A; and
2. certain traffic conditions occur on port 6 of the module
Crash (PR_4874) — The switch may crash with a message similar to:
-> Software exception at alloc_free.c:545 -- in 'eDrvPoll'
Crash (PR_4901) — The switch may crash with a message similar to:
-> Bus Error: HW Addr=0x0000000 IP=0x002fe640 Task='eTelnetd'
This crash has been associated with security/vulnerability test applications such as Nessus.
Loop/VTP (PR_4945) The switch will incorrectly forward VTP packets from third party
devices if that packet is received on a blocked port.
Web-Browser Interface (PR_3634) After clearing the intrusion flag in the web-browser
interface, the intruder flags are not removed.
Release G.05.01
Never released.
Adds support for the ProCurve Switch 4104GL.
Adds support for the J4893A ProCurve Switch GL mini-GBIC module.
Time Zone Issue: Starting with the G.05.xx version of the switch operating system software,
the method of configuring the Time Zone for TimeP or SNTP configuration has been updated.
Previous switch software, for all HP ProCurve switches, used positive time offset values for
time zones that are West of GMT and negative values for time zones that are East of GMT.
The standards indicate that time zones West of GMT should be designated by negative offset
values, and time zones East of GMT by positive values. Software version G.05.xx updates
this configuration method, but if you use the same values for indicating time zones as you
did for previous HP ProCurve switches, the time will be set incorrectly on your Series 4100GL