Control panel message Description Recommended action
RTC (real-time clock) battery may need to
be replaced.
problem persists, replace the RTC battery. See
the Removal and Replacement section for
instructions on installing a new battery.
008–Microcode Patch Error Processor is not supported by the BIOS. 1. Upgrade BIOS to proper version.
2. Change the processor.
009–PMM Allocation Error during MEBx
Download
Memory error during POST execution of the
Management Engine (ME) BIOS Extensions
option ROM.
1. Reboot the computer.
2. Unplug the power cord, re-seat the
memory modules, and reboot the
computer.
3. If the memory conguration was recently
changed, unplug the computer, restore
the original memory conguration, and
reboot the computer.
4. If the error persists, replace the system
board.
00A-Product Information Not Valid The product information programmed into the
system board is missing or invalid.
Use Computer Setup to update this information.
00B-MEBx Module did not checksum correctly Memory error during POST execution of the
Management Engine (ME) BIOS Extensions
option ROM.
1. Reboot the computer.
2. Unplug the power cord, re-seat the
memory modules, and reboot the
computer.
3. If the memory conguration was recently
changed, unplug the power cord, restore
the original memory conguration, and
reboot the computer.
4. If the error persists, replace the system
board.
00C-PMM Deallocation Error during MEBx
Cleanup
Memory error during POST execution of the
Management Engine (ME) BIOS Extensions
option ROM.
1. Reboot the computer.
2. Unplug the power cord, re-seat the
memory modules, and reboot the
computer.
3. If the memory conguration was recently
changed, unplug the power cord, restore
the original memory conguration, and
reboot the computer.
4. If the error persists, replace the system
board.
00D-Setup Error during MEBx Execution MEBx selection or exit resulted in a setup
failure.
1. Reboot the computer.
2. Unplug the power cord, re-seat the
memory modules, and reboot the
computer.
3. If the memory conguration was recently
changed, unplug the power cord, restore
the original memory conguration, and
reboot the computer.
4. If the error persists, replace the system
board.
POST numeric codes and text messages 99

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP ProDesk 600 G2 Series and is the answer not in the manual?

HP ProDesk 600 G2 Series Specifications

General IconGeneral
Processor OptionsIntel Core i3, Intel Core i5, Intel Core i7 (6th Gen)
MemoryUp to 64 GB DDR4
Storage OptionsHDD, SSD
GraphicsIntel HD Graphics, Optional discrete graphics
PortsUSB 3.0, USB 2.0, DisplayPort, VGA, RJ-45
Form FactorSmall Form Factor (SFF), Mini Tower (MT)
Operating SystemWindows 10 Pro, Windows 7 Professional
Expansion SlotsPCIe x16, PCIe x1, PCI
Power Supply200W
DimensionsVaries by form factor
WeightVaries by form factor