Contents 92
Table 12 POST Error Messages
Error-Code Error Message Description / Corrective Action
606 System Fan 4 Missing System fan 1 is not installed, user should install the system
fan. The system will shut down.
607 System Fan 5 Missing System fan 1 is not installed, user should install the system
fan. The system will shut down.
608 System Fan 6 Missing System fan 1 is not installed, user should install the system
fan. The system will shut down.
60F Fan Solution Not Sufficient!
Critical Failure Detected –
System Shutting Down in 15
Second!
The non-redundancy fan is not installed, user should install the
system fan. The system will shut down
601 BMC Not Responding BMC not responding, you can load the optimal default value,
or you must change the LO100 card.
05E Password check failed If user input incorrect password more than three times, then
display this error information and continue to boot. There are
two 'password checked failed'. 05E for setup password.
Checking NVRAM Update
Failed
BIOS could not write to the NVRAM block. This message
appears when the FLASH part is malfunctioning.
Operating system not found
Operating system cannot be located on any of the
boot drives.
Verify that the priority boot drive has power and that
the IDE cable is connected properly.
Verify that the desired boot drive has power
Verify that the IDE cable is securely plugged into the
respective system board connectors.
Verify that the boot device is enabled in the Setup
Utility.
Verify that the boot device has an operating system
installed.
If the problem persists, contact your Foxconn
Customer Support provider
611
System Event Log full
You must enter BIOS SETUP UTILITY and then Clean the
System Event Log
601
Error: BMC Not Responding
BMC not responding, you can load the optimal default value,
or you must change the LO100 card.