EasyManua.ls Logo

HP ProLiant DL180 G6 - Environmental and Physical Dimensions

HP ProLiant DL180 G6
158 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Physical and operating specifications 153
Table 30 Physical Dimensions
Item
Description
System board platform EATX (Extended Advanced Technology Extended)
System board dimension 304.8 mm x 330.2 mm (12 in x 13 in)
Server dimensions (H x W x D)
Rack
87.6 mm x 448.0 mm x 703.4 mm (3.45 in x 17.64 in x
27.69 in)
Server weight Basic configuration (excludes monitor): 16~24kg
Table 31 Environmental Specifications
Item Description
Temperature:
Operating
Non-operating
Storage
Wet-bulb temperature
+10°C to +35°C (+50°F to +95°F)
-30°C to 60°C (-22°F to 140°F)
-30°C to 60°C (-22°F to 140°F)
38.7
°
C (101.7
°
F)
Relative humidity:
Operating
Non-operating
Storage
10% to 90% (non-condensing)
5% to 95%
5% to 95%
Altitude:
Operating
Non-operating
0 to 3049 m (0 to 10,000 ft)
0 to 9146 m (0 to 30,000 ft)
Thermal output (maximum operating)
Acoustic emissions
Normal configuration
1000 W/hr
LWad: 6.7 Bels
(operating at room temperature)
LWad: 6.7 Bels
(Idle at room temperature)

Other manuals for HP ProLiant DL180 G6