Physical and operating specifications 154
Table 32 Power Supply Specifications / 460 W
Item
Description
Dimensions (H x W x D) 38.5 mm x 86.4 mm x 190.5 mm (1.52 in x 3.4 in x 7.5 in)
Weight (approximate) 1.36 kg
Input requirements:
Rated input voltage
Normal line voltage
90 VAC to 264 VAC
100 VAC to 120 VAC/200 VAC to 240 VAC
Line frequency
4763 Hz
Rated input current 6.0 ARMS max @ 100 V
5.0 ARMS max @ 120 V
3.00 ARMS max @ 200 V to 240 V
BTU rating N/A
Power supply output power:
Rated steady state power
Maximum peak power
460 W (1+1 Redundant)
N/A
Temperature range:
Operating
Shipping
+5°C to +50°C
40°C to +85°C
Relative humidity:
Operating
Non-operating
5% to 95% relative humidity, non-condensing
5% to 95% relative humidity, non-condensing
Table 33 Power Supply Specifications / 750 W
Item Description
Dimensions (H x W x D) 38.5 mm x 86.4 mm x 190.5 mm (1.52 in x 3.4 in x 7.5 in)
Weight (approximate) 1.36 kg
Input requirements:
Rated input voltage
Normal line voltage
90 VAC to 264 VAC
100 VAC to 120 VAC/200 VAC to 240 VAC
Line frequency 4763 Hz
Rated input current 9.10 ARMS max @ 100V
5.10 ARMS max @ 200V
BTU rating
N/A
Power supply output power:
Rated steady state power
Maximum peak power
750 W (1+1 Redundant)
N/A