Diagnostics and Troubleshooting
4-44 Compaq ProLiant DL360 Server Maintenance and Service Guide
COMPAQ CONFIDENTIAL Codename: MIcroMachines Part Number: 169616-006 Last Saved On: 12/21/01 9:05 AM
Table 4-16: ADU Diagnostic Messages continued
Message Description Recommended Action
Drive (bay) X
is a
replacement
drive
This drive has been replaced. This
message displays if a drive is
replaced in a fault tolerant logical
volume.
If the replacement was intentional, allow
the drive to rebuild.
Drive (bay) X
is a
replacement
drive marked
OK
This drive has been replaced and
marked OK by the firmware. This
may occur if a drive has an
intermittent failure (for example, if a
drive has previously failed, then
when ADU is run, the drive starts
working again).
Replace the drive.
Drive (bay) X
is failed
The indicated physical drive has
failed.
Replace the drive.
Drive (bay) X
is undergoing
drive recovery
This drive is being rebuilt from the
corresponding mirror or parity data.
Normal operations should occur.
Drive (bay) X
needs
replacing
The 210-megabyte hard drive has
firmware version 2.30 or 2.31.
Replace the drive.
Drive (bay) X
upload code
not readable
An error occurred while ADU was
trying to read the upload code
information from this drive.
If there were multiple errors, this drive may
need to be replaced.
Drive (bay) X
was
inadvertently
replaced
The physical drive was incorrectly
replaced after another drive failed.
Replace the drive that was incorrectly
replaced and replace the original drive that
failed. Do not run the System
Configuration Utility and try to reconfigure;
data will be lost.
Drive
Monitoring
features are
unobtainable
ADU unable to get monitor and
performance data due to fatal
command problem such as drive
time-out, or unable to get data due
to these features not supported on
the controller.
Check for other errors (time-outs, and so
on). If no other errors occur, upgrade the
firmware to a version that supports
monitor and performance, if desired.
Drive
Monitoring is
NOT enabled
for SCSI
Port x Drive
ID x
The monitor and performance
features have not been enabled on
this drive.
Run the System Configuration Utility to
initialize the monitor and performance
features.
Drive time-out
occurred on
physical drive
bay X
ADU issued a command to a
physical drive and the command
was never acknowledged.
The drive or cable may be bad. Check the
other error messages on the Diagnostics
screen to determine resolution.
Drive X
indicates
position Y
Message indicates physical drive
that appears to be scrambled or in
a drive bay other than the one for
which it was originally configured.
Examine the graphical drive
representation on ADU to determine
proper drive locations. Remove drive X
and place it in drive position Y. Rearrange
the drives according to the ADU
instructions.
continued