Diagnostics and Troubleshooting
Compaq ProLiant DL360 Server Maintenance and Service Guide 4-11
COMPAQ CONFIDENTIAL Codename: MIcroMachines Part Number: 169616-006 Last Saved On: 12/21/01 9:05 AM
Table 4-2: POST Error Messages continued
Error Code Audible Beeps
Probable Source of
Problem Recommended Action
211-Cache
Switch Set
Incorrectly
None Switch not set properly
during installation or
upgrade.
Verify switch settings.
212-System
Processor Failed/
Mapped out
1 short Processor in slot x failed. Run Diagnostics and replace
failed processor.
214-DC-DC
Converter Failed
None PowerSafe Module (DC-DC
Converter) failed.
Run Diagnostics. Replace
failed assembly as indicated.
214-Processor
PPM Failed
Module X
None Indicated PPM (DC-DC
Converter) failed.
Replace failed assembly as
indicated.
215-Processor
Power Module
has lost
Redundancy in
Socket x
None PPM (DC-DC Converter)
has lost redundancy.
Run Diagnostics. Replace
failed assembly as indicated.
215-Nonfunctioni
ng Voltage
Regulator Module
for Processors
None PPM (DC-DC Converter)
has failed or lost
redundancy.
Run Diagnostics. Replace
failed assembly as indicated.
216-Voltage
Regulator Module
for Processor X
no longer
redundant
None Redundancy failed in PPM. To restore redundancy, replace
the PPM.
216-Processor
PPM has lost
Redundancy,
Module X
None Indicated PPM (DC-DC
Converter) has lost
redundancy.
Replace failed assembly as
indicated.
218-Cache
Accelerators Not
Installed. System
Halted.
None Cache Accelerators not
installed or improperly
installed.
Check Cache Accelerator
installation.
continued