Diagnostics and Troubleshooting
4-12 Compaq ProLiant DL360 Server Maintenance and Service Guide
COMPAQ CONFIDENTIAL Codename: MIcroMachines Part Number: 169616-006 Last Saved On: 12/21/01 9:05 AM
Table 4-2: POST Error Messages continued
Error Code Audible Beeps
Probable Source of
Problem Recommended Action
219-Tag Update
Rules SRAM
Failure. System
Halted
None Catastrophic chipset failure. Call Compaq service provider.
219-Snoop Rules
SRAM Failure.
System Halted.
None Catastrophic chipset failure. Call Compaq service provider.
220-Cache
Accelerator Slot x
Initialization
Failed. System
Halted.
None Cache Accelerator in slot x
improperly installed or bad.
Check Cache Accelerator
installation and if properly
installed, replace.
221-Power Fault
On Processor
Bus X
None A PPM on indicated bus is
in a failed state.
Run Diagnostics. Replace
failed assembly as indicated.
301-Keyboard
Error
None Keyboard failure Turn off the computer, then
reconnect the keyboard.
301-Keyboard
Error or Test
Fixture Installed
None Keyboard failure Replace the keyboard.
ZZ-301-Keyboard
Error
None Keyboard failure. (ZZ
represents the Keyboard
Scan Code.)
1. A key is stuck. Try to
free it.
2. Replace the keyboard.
303-Keyboard
Controller Error
None System board, keyboard, or
mouse controller failure
1. Run Diagnostics.
2. Replace failed assembly
as indicated.
304-Keyboard or
System Unit Error
None Keyboard, keyboard cable,
or system board failure
1. Make sure the keyboard is
attached.
2. Run Diagnostics to
determine which is in
error.
3. Replace the part indicated.
continued