Diagnostics and Troubleshooting
Compaq ProLiant DL360 Server Maintenance and Service Guide 4-13
COMPAQ CONFIDENTIAL Codename: MIcroMachines Part Number: 169616-006 Last Saved On: 12/21/01 9:05 AM
Table 4-2: POST Error Messages continued
Error Code Audible Beeps
Probable Source of
Problem Recommended Action
40X-Parallel
Port X Address
Assignment
Conflict
2 short Both external and internal
ports are assigned to
parallel port X.
Run the System Configuration
Utility and correct.
601-Diskette
Controller Error
None Diskette controller circuitry
failure
1. Make sure the diskette
drive cables are attached.
2. Replace the diskette drive
and/or cable.
3. Replace the system board.
605-Diskette
Drive Type Error
2 short Mismatch in drive type Run the System Configuration
Utility to set diskette type
correctly.
1151-Com Port 1
Address
Assignment
Conflict
2 short Both external and internal
serial ports are assigned to
COM1.
Run the System Configuration
Utility and correct.
1152-Com Port 2,
3, or 4 Address
Assignment
Conflict
2 short Both external and internal
serial ports are assigned to
COM2, COM3 or COM4.
Run the System Configuration
Utility and correct.
1610-Temperature
violation detected.
Waiting for system
to cool
2 short Ambient system
temperature too hot
Check fan in system
environment.
1611-Fan failure
detected
2 short Required fan not installed
or spinning.
Check fans.
1611-I/O Fan
(Fan X) failure
detected
2 short I/O fan has failed. Replace the failed fan.
1611-CPU Fan
(Fan X) failure
detected
2 short CPU fan has failed. Replace the failed fan.
continued