Diagnostics and Troubleshooting
4-14 Compaq ProLiant DL360 Server Maintenance and Service Guide
COMPAQ CONFIDENTIAL Codename: MIcroMachines Part Number: 169616-006 Last Saved On: 12/21/01 9:05 AM
Table 4-2: POST Error Messages continued
Error Code Audible Beeps
Probable Source of
Problem Recommended Action
1612-Primary
power supply
failure
2 short Primary power supply has
failed.
Replace power supply as soon
as possible.
1613-Low
System Battery
None Real time clock system
battery is running low on
power.
Run Diagnostics. Replace
failed assembly as indicated.
1615-Power
Supply Failure,
Power Supply
Unplugged, or
Power Supply
Fan Failure in
Bay X
None A power supply or power
supply fan has failed.
Replace or check specified
power supply or power supply
fan.
1617-Fan
controller not
responding
2 short Fan controller failure Check and replace failed
controller assembly.
1617-I/O Fan
controller not
responding
2 short I/O fan controller failure Check and replace failed
controller assembly.
1617-CPU Fan
controller not
responding
2 short CPU fan controller failure Check and replace failed
controller assembly.
1618-PCI slots
powered down.
Check PCI hot
plug enabler
connectors.
None PCI hot plug enabler is
missing or failed.
Check and replace missing or
failed assembly.
1620-Locked
SCSI Bus
Detected. Verify
SCSI bus cabling.
System halted.
None SCSI bus failure Run Diagnostics. Replace
failed assembly as indicated.
1621-Current
SCSI bus cable
configuration is
not
recommended
None Improper SCSI bus cabling Check documentation for
proper SCSI bus cabling.
1622-Internal
SCSI Jumper
Board Not
Installed
None The system has detected
that the array enabler board
is not installed.
Install the array enabler board.
continued