Diagnostics and Troubleshooting
Compaq ProLiant DL360 Server Maintenance and Service Guide 4-15
COMPAQ CONFIDENTIAL Codename: MIcroMachines Part Number: 169616-006 Last Saved On: 12/21/01 9:05 AM
Table 4-2: POST Error Messages continued
Error Code Audible Beeps
Probable Source of
Problem Recommended Action
1703-SCSI cable
error detected.
Internal SCSI
cable not
attached to
system board
connector.
System halted.
None Incorrect cabling Ensure that the integrated
SCSI controller has SCSI
termination attached.
1720-Slot x Drive
Array – SMART
Drive Detects
Imminent Failure
SCSI: Port y:
SCSI ID x
None Indicated drive has reported
a SMART predictive-failure
condition and may fail at
some time in the future.
If drive is part of a
nonfault-tolerant configuration,
back up all data before
replacing drive and restore all
data afterward. If drive is part
of a fault-tolerant configuration
do not replace drive unless all
other drives in array are online.
Press the F1 key to resume.
1721-Slot x Drive
Array-Drive
parameter
tracking predicts
imminent failure.
The following
devices should
be replaced when
conditions permit.
Do not replace
the drive unless
all other drives in
the array are
online. Back up
data before
replacing drive(s)
if using RAID 0.
None Monitor and performance
threshold exceeded
condition.
Replace the drive when it is
reasonable. The drive has not
failed, but Compaq
recommends you replace the
drive.
* 1724-Slot x
Drive Array –
Physical Drive
Position
Change(s)
Detected –
Logical drive
configuration has
automatically
been updated
None Logical drive configuration
has been updated
automatically following
physical drive position
changes.
Press the F1 key to resume.
continued