Diagnostics and Troubleshooting
Compaq ProLiant DL360 Server Maintenance and Service Guide 4-17
COMPAQ CONFIDENTIAL Codename: MIcroMachines Part Number: 169616-006 Last Saved On: 12/21/01 9:05 AM
Table 4-2: POST Error Messages continued
Error Code Audible Beeps
Probable Source of
Problem Recommended Action
1740-Fixed
Disk 0 failed Set
Block Mode
command
None Hard drive error Run the System Configuration
Utility and correct.
1741-Fixed
Disk 1 failed Set
Block Mode
command
None Hard drive error Run the System Configuration
Utility and correct.
1750-Fixed
Disk 0 failed
Identify command
None Hard drive error Run the System Configuration
Utility and correct.
1751-Fixed
Disk 1 failed
Identify command
None Hard drive error Run the System Configuration
Utility and correct.
1760-Fixed
Disk 0 does not
support Block
Mode
None Hard drive error Run the System Configuration
Utility and correct.
1761-Fixed
Disk 1 does not
support Block
Mode
None Hard drive error Run the System Configuration
Utility and correct.
1764-Slot x Drive Array - Capacity Expansion Process is temporarily
disabled (followed by one of the following):
Expansion will resume when Array Accelerator has been
reattached.
Expansion will resume when Array Accelerator has been
replaced.
Expansion will resume when Array Accelerator RAM allocation is
successful.
Expansion will resume when Array Accelerator battery reaches
full charge.
Expansion will resume when automatic data recovery has been
completed.
Reattach or replace array
accelerator, wait until the array
accelerator batteries have
charged, or for Automatic Data
Recovery to complete, as
indicated.
1767-Slot x Drive Array Option ROM is Not Programmed Correctly or
may Conflict with the Memory Address Range of an ISA Card. Check
the Memory Address Configuration of installed ISA Card(s) or run
Options ROMPaq Utility to attempt SMART-2/E Option ROM
Reprogramming.
Remove or reconfigure
conflicting ISA cards,
especially any cards that are
not recognized by the System
Configuration Utility. Try
reprogramming the ROM on
the SMART-2/E Controller
using the latest Options
ROMPaq (version 2.29 or
higher).
continued