Diagnostics and Troubleshooting
Compaq ProLiant DL360 Server Maintenance and Service Guide 4-19
COMPAQ CONFIDENTIAL Codename: MIcroMachines Part Number: 169616-006 Last Saved On: 12/21/01 9:05 AM
Table 4-2: POST Error Messages continued
Error Code Audible Beeps
Probable Source of
Problem Recommended Action
1772-Secondary
Disk Port
Address
Assignment
Conflict
None Address Assignment
Conflict. Internal and
external hard drive
controllers are both
assigned to the secondary
address.
Run the System Configuration
Utility and correct.
1773-Primary
Fixed Disk Port
Assignment
Conflict
None Fixed disk drive error Run the System Configuration
Utility and correct.
1774-Slot x Drive
Array - Obsolete
data found in
Array
Accelerator.
Select F1 to
discard contents
of Array
Accelerator.
Select F2 to write
contents of Array
Accelerator to
drives.
None SMART-2 Controller error Data found in array accelerator
is older than data found on
drives. Press the F1 key to
discard the older data in the
array accelerator and retain the
newer data on the drives.
1775-Slot x Drive
Array –
ProLiant DL360
Storage System
Not Responding
SCSI Port (y):
Check storage
system power
switch and
cables. Turn the
system power off
while checking
the ProLiant
DL360 server
power and cable
connections, then
turn the system
power back on to
retry.
None Storage system problem Turn off power to system.
Check external ProLiant DL360
server power switch – external
drives must all be powered up
before or at the same time as
the main system. Check
cables. If retry does not help,
try replacing the cable,
ProLiant DL360 server
firmware, ProLiant DL360
server backplane, or the Smart
Array Controller.
Press the F1 key to resume.
continued