Removal and replacement procedures 62
o
2 SFF rear drive cage
To replace the component, reverse the removal procedure.
If no replacement drive cage is installed, do one of the following:
o Install the secondary PCI riser cage blank.
o Install the LFF rear drive cage blank.
Flash-backed write cache procedures
The following types of procedures are provided for the FBWC option:
Removal and replacement of failed components:
o Removing the cache module ("FBWC module" on page 62)
o Removing the capacitor pack ("Capacitor pack" on page 64)
o Removing the capacitor pack holder ("Capacitor pack holder" on page 65)
Recovery of cached data from a failed server ("Recovering data from the flash-backed write cache" on
page 66)
CAUTION: Do not detach the cable that connects the battery pack or capacitor pack to the cache
module. Detaching the cable causes all data in the cache module to be lost.
FBWC module
CAUTION: The cache module connector does not use the industry-standard DDR3 mini-DIMMs.
Do not use the controller with cache modules designed for other controller models, because the
controller can malfunction and you can lose data. Also, do not transfer this cache module to an
unsupported controller model, because you can lose data.
CAUTION: In systems that use external data storage, be sure that the server is the first unit to be
powered down and the last to be powered back up. Taking this precaution ensures that the system
does not erroneously mark the drives as failed when the server is powered up.