EasyManuals Logo

HP ProLiant series User Manual

HP ProLiant series
139 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #119 background imageLoading...
Page #119 background image
Error messages 119
Interconnect B Error Code
LED code: 14-1, 14-2, 14-3, or 14-4
Location: Interconnect device - side B
Action: Perform the following steps to resolve the problem. Stop when the problem is resolved.
1. Press the server blade management module reset button.
2. Reseat the interconnect device.
For more information, refer to the HP BladeSystem Maintenance and Service Guide on the HP
website (http://www.hp.com/products/servers/proliant-bl/p-class/info
).
3. Replace the interconnect device.
For more information, refer to the HP BladeSystem Maintenance and Service Guide on the HP
website (http://www.hp.com/products/servers/proliant-bl/p-class/info
).
Interconnect Module A (10-Connector) Error Code
LED code: 15-1 or 15-2
Location: Interconnect module - side A (10-connector)
Action: Perform the following steps to resolve the problem. Stop when the problem is resolved.
1. Press the server blade management module reset button.
2. Reseat the interconnect module.
For more information, refer to the HP BladeSystem Maintenance and Service Guide on the HP
website (http://www.hp.com/products/servers/proliant-bl/p-class/info
).
3. Replace the interconnect module.
For more information, refer to the HP BladeSystem Maintenance and Service Guide on the HP
website (http://www.hp.com/products/servers/proliant-bl/p-class/info
).
Interconnect Module A (6-Connector) Error Code
LED code: 17-1 or 17-2
Location: Interconnect module - side A (6-connector)
Action: Perform the following steps to resolve the problem. Stop when the problem is resolved.
1. Press the server blade management module reset button.
2. Reseat the interconnect module.
For more information, refer to the HP BladeSystem Maintenance and Service Guide on the HP
website (http://www.hp.com/products/servers/proliant-bl/p-class/info
).
3. Replace the interconnect module.
For more information, refer to the HP BladeSystem Maintenance and Service Guide on the HP
website (http://www.hp.com/products/servers/proliant-bl/p-class/info
).
Interconnect Module B (10-Connector) Error Code
LED code: 16-1 or 16-2
Location: Interconnect module - side B (10-connector)
Action: Perform the following steps to resolve the problem. Stop when the problem is resolved.
1. Press the server blade management module reset button.
2. Reseat the interconnect module.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP ProLiant series and is the answer not in the manual?

HP ProLiant series Specifications

General IconGeneral
CategoryServer
SeriesProLiant
ManufacturerHP
Processor SupportIntel Xeon, AMD Opteron
Memory SupportDDR3, DDR4
Storage SupportSATA, SAS, SSD
Form FactorTower, Rackmount, Blade
NetworkingGigabit Ethernet, 10Gb Ethernet
ManagementiLO (Integrated Lights-Out)
Power SupplyRedundant power supply options
Operating System SupportWindows Server, Linux, VMware

Related product manuals