Support Saves may take a long time with large databases
As databases grow larger from Event, sFlow, and Performance Collector data, the support save
operation may take a long time to run. Larger databases promote longer support save operations.
Make sure you have a minimum of 20–GB disk space for support save and backup operations.
Table 5 Performance Counter calculation formulas
FormulaSource valueProtocol
used
TypeCounter Name
TX = (Delta value1 / (1000 * 1000))
/ (Polling interval2/1000)
.1.3.6.1.3.94.4.5.1.6SNMPFCTX
RX = (Delta value1 / (1000 * 1000))
/ (Polling interval2/1000)
.1.3.6.1.3.94.4.5.1.7SNMPFCRX
TX = (Delta value1 / (1000 * 1000))
/ (Polling interval2/1000)
.1.3.6.1.2.1.31.1.1.1.10SNMPGETX
RX = (Delta value1 / (1000 * 1000))
/ (Polling interval2/1000)
.1.3.6.1.2.1.31.1.1.1.6SNMPGERX
TX = (Delta value1 / (1000 * 1000))
/ (Polling interval2/1000)
.1.3.6.1.2.1.31.1.1.1.10SNMPFCIPTX
RX = (Delta value1 / (1000 * 1000))
/ (Polling interval2/1000)
.1.3.6.1.2.1.31.1.1.1.6SNMPFCIPRX
TX = (Delta value1 / (1000 * 1000))
/ (Polling interval2/1000)
PortRX (variable from the
return html file)
HTTPEE Monit-
ors
TX
RX = (Delta value1 / (1000 * 1000))
/ (Polling interval2/1000)
PortTX (variable from the
return html file)
HTTPEE Monit-
ors
RX
TX = (Delta value1 / (1000 * 1000))
/ (Polling interval2/1000)
N/AHCM
API
HBA,
CNA
TX
RX = (Delta value1 / (1000 * 1000))
/ (Polling interval2/1000)
N/AHCM
API
HBA,
CNA
RX
TX = (Delta value1 / 1000) / (1000
* 1000)
. 1.3.6.1.2.1.2.2.1.11 +
.1.3.6.1.2.1.31.1.1.1.2 +
.1.3.6.1.2.1.31.1.1.1.3
SNMPTETX
RX = (Delta value1 / 1000) / (1000
* 1000)
. 1.3.6.1.2.1.2.2.1.17 +
.1.3.6.1.2.1.31.1.1.1.4 +
.1.3.6.1.2.1.31.1.1.1.5
SNMPTERX
TX% or RX% = ((TX or RX) /
((105000000 * port speed)*( Polling
interval2/ 1000.00))) * 100 If Utiliz-
ation is less than 1 then the value is it
to 0.0
N/AN/AFC, GE,
FCIP,
HBA,
CNA
TX% / RX%
value = (TX or RX) / 10; TX% or RX%
= ((value) / ((105000000 * port
speed)*( 1000/ 1000.00))) * 100 if
Utilization is less than 1 then the value
is it to 0.0
N/AN/ATETX% / RX%