FormulaSource valueProtocol
used
TypeCounter Name
Compression Ratio = current value/
1000 Since for compression ratio we
will take the current compression ratio
value
.1.3.6.1.4.1.1588.4.1.1.4N/AFCIPCompression
Ratio
Receive EOF = Delta value1 / (1000
* 1000)
.1.3.6.1.2.1.16.1.1.1.5N/ATEReceive EOF
Other counters = Delta value
1
N/AN/AN/AOther Counters
1. Delta value is the difference of value retrieved between the two consecutive poling cycles.
2. Polling interval duration between the two polling cycle
Table 6 Other countries' counters
Source valueProtocol usedTypeCounter Name
.1.3.6.1.3.94.4.5.1.40SNMPFCCRC Errors
.1.3.6.1.3.94.4.5.1.43SNMPFCSignal Losses
.1.3.6.1.3.94.4.5.1.44SNMPFCSync Losses
.1.3.6.1.3.94.4.5.1.39SNMPFCLink Failures
.1.3.6.1.3.94.4.5.1.42SNMPFCSequence Errors
.1.3.6.1.3.94.4.5.1.41SNMPFCInvalid Transmissions
.1.3.6.1.3.94.4.5.1.33SNMPFCRx Link Resets
.1.3.6.1.3.94.4.5.1.34SNMPFCTx Link Resets
.1.3.6.1.3.94.4.5.1.28SNMPFCC3 Discard
.1.3.6.1.4.1.1588.4.1.1.5SNMPFCIPLatency
.1.3.6.1.4.1.1588.4.1.1.3SNMPFCIPDropped Packets
.1.3.6.1.4.1.1588.4.1.1.2SNMPFCIPLink Retransmits
.1.3.6.1.4.1.1588.4.1.1.9SNMPFCIPTimeout Retransmits
.1.3.6.1.4.1.1588.4.1.1.10SNMPFCIPFast Retransmits
.1.3.6.1.4.1.1588.4.1.1.11SNMPFCIPDuplicate Ack Received
.1.3.6.1.4.1.1588.4.1.1.12SNMPFCIPWindow Size RTT
.1.3.6.1.4.1.1588.4.1.1.13SNMPFCIPTCP Out of Order Segments
.1.3.6.1.4.1.1588.4.1.1.14SNMPFCIPSlowStart Status
PortCRC (variable from the return
html file)
HTTPEE MonitorsCRC Errors
HP Network Advisor B-series Enterprise, Professional Plus, and Professional 11.1.1 Release
Notes 15