Remote Control Unit function
Change RCU Option
Change Remote Control Unit Option operation
Normal end
The operation has ended normally.
Seq.=xxxxxx
Sequence number of log information (0000000000 to 4294967295)
Detailed Information
Detailed information displays for this operation, as shown in Table 236.
Table 236 Change RCU Option
DescriptionItem
Indicates a serial number of the RCU device where the RCU option setting is changed.S/N
The LDKC number of the connected LDKC.MCU LDKC
The LDKC number of the paired LDKC.RCU LDKC
The RCU path group ID where the RCU optional setting is changed. When the path
group ID is default setting, Default is output.
Path Gr.ID
The controller ID of the RCU where the optional setting is changed.Controller ID
The CU number of the connected CU.MCU
Indicates SSID of the RCU where the optional setting is changed.SSID
The minimum number of paths after change.Min.Path
The value of RIO MIH (Remote I/O Missing Interrupt Handler) timer (wait time until data
copy from MCU to RCU is completed). The unit represents seconds.
MIH Time(s)
The round-trip response time (delay time for round-trip remote I/O) after change. The
unit is in milliseconds. This value is output when HP XP Continuous Access Software or
TrueCopy for Mainframe is used.
Round Trip
Time(ms)
The incident of RCU after change. This value is output only when TrueCopy for Mainframe
is used.
only to RCU host: RCU host only, to any host.
Incident
Indicates whether CGROUP (FREEZE/RUN) PPRC TSO command support is enabled or
disabled. This value is output only when TrueCopy for Mainframe is used.
Enable or Disable is output.
FREEZE
Delete Path Operation
Example 1 (CU Free is used)
Remote Control Unit (RCU) Function260