HP Tower UPS
User Guide
Abstract
This document is for the person who installs and maintains HP UPS products. HP assumes you are qualified
in the installation of electrical equipment and trained in recognizing hazards in products with hazardous
energy levels.
Part Number: 792523-001
November 17, 2014
Edition: 1

Questions and Answers

  • Z
    zcollinsAug 8, 2025
    What to do if my HP T1500 G4 NA/JP UPS is overloaded?
    • C
      christytateAug 9, 2025
      If your HP UPS is overloaded, it means the power requirement exceeds the UPS capacity (greater than 105% of nominal). To resolve this, remove some of the equipment from the UPS. The UPS will continue to operate, but might shut down if the load increases. The alarm will reset when the condition becomes inactive.
  • J
    Joyce WattsAug 14, 2025
    Why does my HP T1500 G4 NA/JP have a battery fault?
    • M
      Mary StoneAug 15, 2025
      A battery fault in your HP UPS can occur for a couple of reasons: * The batteries in the UPS might be disconnected. Verify that all batteries are properly connected. If the error persists, note the alarm message and the UPS serial number, and then contact your service representative. * The end of battery life might be reached. If this is the case, contact your service representative for battery replacement.
  • A
    Aaron WalkerAug 19, 2025
    What to do if my HP T1500 G4 NA/JP UPS has a short-circuit fault?
    • H
      holly71Aug 19, 2025
      If your HP UPS indicates a short-circuit fault, it means a short-circuit has occurred. Check the device connection or integrity. If the error persists, note the alarm message and the UPS serial number, and then contact your service representative.
  • Z
    zavalamatthewAug 27, 2025
    How to fix a fan fault on my HP T1500 G4 NA/JP UPS?
    • R
      Ryan CampbellAug 27, 2025
      If your HP UPS is showing a fan fault, check that no object is blocking the fan. If the error persists, note the alarm message and the UPS serial number, and then contact your service representative.
  • M
    Miguel CastanedaSep 1, 2025
    What does it mean if my HP T1500 G4 NA/JP has a charger fault?
    • L
      Lisa HernandezSep 1, 2025
      If your HP UPS has a charger fault, it means the UPS is no longer charging the battery. Note the alarm message and the UPS serial number, and then contact your service representative.

Summary

IMPORTANT SAFETY INSTRUCTIONS

Personal Safety

Product Safety

Special Precautions

Control Panel

LCD Window Overview

UPS Settings via LCD

Battery Module Connection

Operation

Start-up and Normal Operation

Step-by-step guide to starting the UPS and ensuring normal operation.

Operation on Battery Power

Details how the UPS operates when AC power is lost, including low-battery warnings.

Troubleshooting

Battery Module Safety Precautions

Battery Replacement and Care

Important Battery Safety Warnings

Specific warnings regarding fire or chemical burns when handling battery modules.

Battery Module Removal

Step-by-step instructions for the physical removal of the battery module from the UPS.

Technical Specifications (NA;JP Models)

Technical Specifications (INTL Models)

HP T1500 G4 NA/JP Specifications

General IconGeneral
Nominal output voltage100V, 120V
Nominal input voltage100V, 120V
Input connection typeNEMA 5-15P
Typical recharge time3 hour(s)
Interface PortUSB
Capacity1500 VA
Frequency50/60 Hz +/- 3 Hz auto-sensing
WaveformStepped approximation to a sinewave
Operating Temperature0 - 40 °C
Storage Temperature-15 - 45 °C
Output power capacity1500 VA / 1000 W
Output ConnectionsNEMA 5-15R
Control panelLED status display
Audible alarmAlarm when on battery
Battery TypeMaintenance-free sealed Lead-Acid battery with suspended electrolyte
Relative Humidity0 - 95% (Non-condensing)
Safety ApprovalsFCC Part 15 Class B

Related product manuals