HP 2U UPS
User Guide
Abstract
This document is for the person who installs and maintains HP UPS products. HP assumes you are qualified
in the installation of electrical equipment and trained in recognizing hazards in products with hazardous
energy levels.
Part Number: 792519-001
November 17, 2014
Edition: 1

Questions and Answers

  • T
    Timothy WardAug 8, 2025
    What to do if my HP UPS battery life ends?
    • A
      Adam SantosAug 8, 2025
      If your HP UPS indicates the end of battery life, this means the battery has reached its end. Contact your service representative for battery replacement.
  • C
    Christopher WoodAug 16, 2025
    What to do if my HP UPS is overloaded?
    • R
      Ryan HensonAug 16, 2025
      If your HP UPS is overloaded, it means the power requirements exceed the UPS capacity (greater than 105% of nominal). To resolve this, remove some of the equipment from the UPS. The UPS will continue to operate but may shut down if the load increases further. The alarm will reset when the overload condition is no longer present.
  • B
    Belinda PattonAug 25, 2025
    Why does my HP R/T3000 G4 INTL UPS show a fault?
    • F
      Frank HerringAug 25, 2025
      If your HP UPS shows a fault, it indicates that the UPS has an internal fault and is not protecting the equipment. Record the alarm message and the UPS Serial Number, then contact your service representative.
  • J
    Jeffery ThomasAug 31, 2025
    How to fix HP R/T3000 G4 INTL UPS when batteries are disconnected?
    • E
      Emily LinAug 31, 2025
      If your HP UPS indicates that the batteries are disconnected, it could be due to the UPS not recognizing the internal batteries, or the batteries being physically disconnected. Verify that all batteries are properly connected. If the condition persists, contact your service representative.

Summary

Important Safety Instructions

Personal Safety

Product Safety

Special Precautions

Installation

Battery Module Connection

Procedure for connecting the internal battery module.

Rack Installation

Instructions for mounting the UPS in a standard equipment rack.

Communication Ports

Details how to connect communication cables for monitoring and control.

UPS Connection

Steps for connecting the UPS to the AC power source and loads.

ERM and UPS Installation

Guide for installing Extended Runtime Modules (ERMs) with the UPS.

Operation

Start-up and Normal Operation

Procedure for powering on the UPS and verifying normal operation.

Maintenance

Troubleshooting

Lists common operational issues and their solutions.

Battery Module Replacement

Step-by-step guide for replacing the UPS battery module.

Technical Specifications

HP R;T2200 G4 NA;JP UPS and HP R;T3000 G4 LV NA;JP UPS

Technical specifications for specific UPS models.

HP R;T3000 G4 HV NA;JP UPS and HP R;T3000 G4 INTL UPS

Technical specifications for specific UPS models.

HP R/T3000 G4 INTL Specifications

General IconGeneral
Input Frequency50/60 Hz
Output Connections(8) IEC 320 C13, (1) IEC 320 C19
Input Connection TypeIEC 320 C20
Rack Height2U
Battery TypeSealed Lead Acid (SLA)
Battery Recharge Time3 hours
Operating Humidity0% to 95% non-condensing
Output Power Capacity2700 W
Form FactorRackmount/Tower
Interface PortsUSB, Serial
Operating Temperature0°C to 40°C