Ensure that the ambient air temperature falls within the environmental specifications listed in this
document.
NOTE: The ambient upper limit of 35 C is only good up to 1524 m (5000 ft) elevation. There is
a 1 C per 304.8 m (1000 ft) derating above 1524 m (5000 ft). So, at 3,048 m (10,000 ft), the
upper ambient air temperature limit is 30 C.
For cabinet installation, ensure adequate cabinet ventilation and ensure that the ambient
temperature within the cabinet does not exceed specified limits.
Never restrict the incoming or outgoing airflow of the workstation by blocking any vents or air
intakes as shown in the following figure.
Figure 3-2 Proper workstation placement
20 Chapter 3 Setting up the workstation