QuickSpecs
Aruba Instant On 1830 Switch Series
Specifications
Page 12
Aruba Instant
On 1830 8G
Switch
(JL810A)
Aruba Instant
On 1830 8G 4p
Class4 PoE
65W Switch
(JL811A)
Aruba Instant
On 1830 24G
2SFP Switch
(JL812A)
Aruba Instant
On 1830 24G
12p Class4
PoE 2SFP
195W Switch
(JL813A)
Aruba Instant
On 1830 48G
4SFP Switch
(JL814A)
Aruba Instant
On 1830 48G
24p Class4
PoE 4SFP
370W Switch
(JL815A)
Performance
100 Mb
latency
< 5.2 uSec
< 5.2 uSec
< 5.2 uSec
< 5.2 uSec
< 5.2 uSec
< 5.2 uSec
1000 Mb
latency
< 2.8 uSec
< 2.8 uSec
< 2.8 uSec
< 2.8 uSec
< 2.8 uSec
< 2.8 uSec
10000 Mb
latency
n/a
n/a
n/a
n/a
n/a
n/a
Throughput
(Mpps)
11.90 Mpps
11.90 Mpps
38.68 Mpps
38.68 Mpps
77.37 Mpps
77.37 Mpps
Capacity
16 Gbps
16 Gbps
52 Gbps
52 Gbps
104 Gbps
104 Gbps
MAC address
table size (# of
entries)
8,000 entries
8,000 entries
16,000 entries
16,000 entries
16,000 entries
16,000 entries
Reliability
MTBF (years)
188.2
105.9
203.6
96.6
114.4
83.5
Environment
Operating
temperature
32°F to 104°F
(0°C to 40°C)
32°F to 104°F
(0°C to 40°C)
32°F to 104°F
(0°C to 40°C)
32°F to 104°F
(0°C to 40°C)
32°F to 104°F
(0°C to 40°C)
32°F to 104°F
(0°C to 40°C)
Operating
relative
humidity
15% to 95% @
104°F (40°C)
15% to 95% @
104°F (40°C)
15% to 95% @
104°F (40°C)
15% to 95% @
104°F (40°C)
15% to 95% @
104°F (40°C)
15% to 95% @
104°F (40°C)
Nonoperating/
storage
temperature
-40°F to 158°F
(-40°C to
70°C)
-40°F to 158°F
(-40°C to 70°C)
-40°F to 158°F
(-40°C to 70°C)
-40°F to 158°F
(-40°C to 70°C)
-40°F to 158°F
(-40°C to 70°C)
-40°F to 158°F
(-40°C to 70°C)
Nonoperating/
storage
relative
humidity
15% to 95% @
140°F (60°C)
15% to 95% @
140°F (60°C)
15% to 95% @
140°F (60°C)
15% to 95% @
140°F (60°C)
15% to 95% @
140°F (60°C)
15% to 95% @
140°F (60°C)
Altitude
up to 10,000 ft
(3 km)
up to 10,000 ft
(3 km)
up to 10,000 ft
(3 km)
up to 10,000 ft
(3 km)
up to 10,000 ft
(3 km)
up to 10,000 ft
(3 km)
Acoustics
1
Fanless
Fanless
Fanless
LWAd = 3.1 Bel
LpAm
(Bystander) =
17 dB
LWAd = 3.4 Bel
LpAm
(Bystander) =
19 dB
LWAd = 4.0 Bel
LpAm
(Bystander) =
25 dB
Notes:
1
Acoustics measured in 23°C semi-anechoic chamber with a loading of 100% traffic and (for
JL813A and JL815A) 50% PoE on all ports. Measured in accordance with ISO 7779. Declared in accordance
with ECMA-109:2010. Values presented are the Declared A-Weighted Sound Power Level (LWAd) and the
mean Bystander A-Weighted Sound Pressure Level (LpAm)
100% traffic
Fanless
Fanless
Fanless
LWAd = 3.1 Bel
LpAm
(Bystander) =
17 dB
LWAd = 3.4 Bel
LpAm
(Bystander) =
19 dB
LWAd = 3.5 Bel
LpAm
(Bystander) =
20 dB
100% traffic /
0% PoE
Fanless
Fanless
Fanless
LWAd = 3.1 Bel
LpAm
(Bystander) =
17 dB
LWAd = 3.5 Bel
LpAm
(Bystander) =
20 dB