Loading...
Cabling upgrade enclosures
Labeling the cables
The StoreOnce upgrade storage enclosure includes a sheet of preprinted cable label pairs. Each pair
contains two identical labels, one for each end of the SAS cable.
These labels use this convention: N:S3:P1 - J1:D1:IA:P1 or JF:D2:IB:P2, where
N = Node (server node)
S = Slot
P = Port
J = JBOD
D = Drawer
I = I/O module
F = Floating number (for moving cables)
Apply the correct pair of labels to each SAS cable as you cable the storage enclosure.
When labeling moving cables that require the additional "F=" label:
Wrap each label around one cable path only.
Apply the labels so the orientation of the lettering matches the orientation of the manufacturer mark.
Place the "F=" label farthest from the connector.