  • C
    Carolyn ThorntonSep 8, 2025
    What does fault of input phase mean on hpmont Inverter?
    • J
      jessemcdonaldSep 9, 2025
      If your hpmont three-phase input inverter shows a fault of input phase, it means a phase loss fault has occurred to the power input; check the three-phase power input. If this doesn't solve your problem, seek technical support.
  • T
    Tina WestAug 23, 2025
    Why is my hpmont HD30-4T015G/018P Inverter showing DC bus over voltage during acceleration?
    • R
      Rebecca SmithAug 23, 2025
      DC bus over voltage during acceleration in your hpmont Inverter can occur due to several reasons. The input voltage might be too high, so check the power input. Also, the deceleration time could be too short; adjust it using parameters F03.02, F03.04, F03.06, and F03.08. Improper wiring can also lead to overvoltage, so inspect the wiring and ensure the inverter is wired correctly. If an instant stop occurred and the motor restarted, set the start mode to speed tracking (F02.00=2). Finally, ensure that the braking devices are properly selected according to the user manual's recommendations.
  • A
    Adam AndersonAug 25, 2025
    How to fix hpmont HD30-4T015G/018P output overcurrent during acceleration?
    • O
      orozcodevinAug 26, 2025
      To resolve an hpmont Inverter output overcurrent during acceleration, consider these potential causes. Ensure proper connection between the inverter and the motor. Verify and correct motor parameters using F08.00, F08.04, F13.01, and F13.05. If the inverter's rating is too small, select one with a higher rating. Also, adjust the acceleration and deceleration times using parameters F03.01 and F03.08. If an instant stop occurs and the motor restarts, set the start mode to speed tracking (F02.00=2).
  • W
    William ChapmanAug 26, 2025
    What causes a motor overload on my hpmont Inverter?
    • T
      Tina CrawfordAug 27, 2025
      A motor overload on your hpmont Inverter can stem from several causes. An improper setting of the V/f curve can be a factor, so adjust it using parameters F09.00-F09.06. Also, a low mains supply voltage can contribute, so check the power input. If the motor runs for a long time with a heavy load at low speed, consider using a special motor designed for such conditions. Ensure the motor’s overload protection factor is properly set. Finally, check for a blocked torque or an excessively heavy load, and inspect the load and mechanical transmission devices.
  • M
    Marc WrightAug 27, 2025
    What to do if my hpmont Inverter shows DC bus undervoltage?
    • J
      Joshua FletcherAug 27, 2025
      DC bus undervoltage on your hpmont Inverter can be caused by a few things. First, check the input power voltage to ensure it is not too low. If it is, correct it. Also, improper wiring can lead to undervoltage, so verify the wiring and ensure the inverter is wired correctly. Note that this can be a normal status during powering on and powering off.
  • J
    John ReyesSep 22, 2025
    What does access fault of control board EEPROM mean on hpmont HD30-4T015G/018P Inverter?
    • T
      Tiffany ZhangSep 22, 2025
      An access fault of the control board EEPROM on your hpmont Inverter indicates a memory circuit fault of the control board EEPROM. Contact the supplier for repairing.
  • M
    Mary AllisonSep 16, 2025
    What to do if there is a fault of current detection circuit on hpmont Inverter?
    • A
      Ann SpencerSep 16, 2025
      If there is a fault of the current detection circuit on your hpmont Inverter, indicating that the current detection circuit is damaged, contact the supplier for repair.
  • K
    Kenneth JenkinsSep 18, 2025
    What does access fault of display panel EEPROM mean on hpmont Inverter?
    • D
      Dawn MooreSep 18, 2025
      An access fault of the display panel EEPROM on your hpmont Inverter indicates a memory circuit fault of the display panel EEPROM. You can try replacing the display panel. If the problem persists, contact the supplier for repairing.
  • Y
    yrangelSep 7, 2025
    What causes parameters auto-tuning fault on hpmont Inverter?
    • M
      Miguel HughesSep 7, 2025
      A parameters auto-tuning fault on your hpmont Inverter can occur if the parameter auto-tuning times out, so check the motor’s connection. Ensure that you input the correct motor parameters (F08.00, F08.04, F13.01, F13.05). If problems persist, seek technical support.
  • A
    Allen PerkinsSep 4, 2025
    Why am I getting a fault setting of parameters error on my hpmont Inverter?
    • B
      Brittany SchmittSep 4, 2025
      A fault in the parameter settings of your hpmont Inverter can occur if the power rating between the motor and inverter is too different; select an inverter with a suitable power rating. It can also be due to improper setting of motor parameters, so set the correct values for motor parameters (F08.00, F08.04, F13.01, F13.05).

Summary

Chapter 1 Safety Information and Precautions

1.1 Safety Definition

Defines hazard symbols like Danger, Warning, and Note for user safety.

1.3 Installation Limitation

Outlines restrictions and considerations for inverter installation to prevent damage.

Chapter 2 Product Information

2.3 Specifications

Lists the electrical, performance, and characteristic specifications of the HD30 series inverter.

Chapter 3 Mechanical Installation

3.1 Installation Precautions

Provides essential safety warnings and steps before and during mechanical installation.

Chapter 4 Electrical Installation

4.1 Wiring Precautions

Lists critical safety guidelines and warnings for electrical wiring procedures.

Chapter 5 Operation Instructions

Chapter 6 Function Introduction

6.2 Group F: General Function Parameters

Introduces general function parameters grouped into various sub-groups (F00-F23).

Chapter 7 Troubleshooting

Appendix A Parameters

Group F00 Basic Parameter

Covers fundamental parameters like control mode, inverter type, and frequency settings.

hpmont HD30-4T015G/018P Specifications

General IconGeneral
Brandhpmont
ModelHD30-4T015G/018P
CategoryInverter
LanguageEnglish

Related product manuals