not exceed the warranty period.
4.Directly handle bulging modules, no matter how long they are stored.
5.Battery performance degradation after long-term storage, please shorten shelf time as possible
as you can.
4.7.3 Recharge process
Recharge the module using a power system:Connect the positive and negative terminals of the
module to the output positive and negative terminals on the DC regulated power supply,
respectively.
Recharge parameter setting
Using the default charge current limit; typically ≤ 0.2C
The charge duration is greater than 10 minutes and the charge
current is less than 0.03C, or the BMS is protected.
Note:Do not perform operations with power on when connecting the recharge cables.
4.8 – Maintenance
Please clean the dust by the dust collector when dust is accumulated on vent
Please use clean and dry cloth/fabric to clean up the cabinet, if need further cleaning, please
use neutral cleanser. Alcohol or ammonia synthesis is forbidden.
Carrying shall be handled gently, prevent from severe compact
Prevent battery from splashing liquid
Suggest inspect the tighten of output screw every two years