EasyManua.ls Logo

Huawei FusionServer G5500 - 3.3 Removing the G560

Huawei FusionServer G5500
59 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
43
www.huawei.com Huawei Confidential 43
Dell: PowerEdge C4130
Parameter G5500-G560 PowerEdge C4130
Dimensions (H x W x D)
4U (175*447*790) 1U (43*439*885)
Architecture Modular Integrated
CPU 2S + 24DIMM 2S + 16DIMM
Maximum CPU power 300 W 145 W
GPU 8*P100/P40 4*P100/P40
Maximum GPU power 350 W 300 W
CPU:GPU topology 1:8/1:4 flexible configuration 1:4/1:2
Hard drive
6*2.5'' NVMe SSD
2*2.5'' SAS/SATA HDD
8*3.5'' HDD
2*1.8'' SATA SSD
It can be configured with the PSU2.
4*2.5'' SAS/SATA SSD/HDD
RAID RAID 0/1/10/5/50/6/60 Pluggable Raid card (occupying the extended slot of PCIe)
PCIe expansion 4*PCIe x16 2*PCIe x16
On-board network adapter / 2*GE
Power supply 4*2200 W hot swap, 2+2 2*2000 W hot swap, 1+1
Fan 6 hot swap, 5+1 The built-in does not support hot swap. When the fan fails,
heat dissipation is affected.
Temperature
5°C to 35°C 10°C to 25°C
Beating Points
The integrated design of the chassis does not support independent evolution of the CPUs and GPUs.
The CPU supports only up to 145 W, which restricts support for the Scalable Processors in the future.
Only 16 DIMMs are supported, and the memory capacity is limited.
NVMe SSD is not supported. (Hard drives and PSU2 alternatively supported)
The fans are built-in and require opening the chassis for maintenance.
The supported temperature is only 10°C to 25°C, and the application is restricted.
The internal GPU cards, PCIe expansion slots, and extended hard drives need to be connected, which
makes maintenance complicated.

Other manuals for Huawei FusionServer G5500

Related product manuals