44
www.huawei.com ▪ Huawei Confidential ▪ 44
Dell: PowerEdge C4130
Parameter G5500-G560 PowerEdge C4130
Dimensions (H x W x D)
4U (175*447*790) 1U (43*439*885)
Architecture Modular Integrated
CPU 2S + 24DIMM 2S + 16DIMM
Maximum CPU power 300 W 145 W
GPU 8*P100/P40 4*P100 NVLink
Maximum GPU power 350 W 300 W
CPU:GPU topology 1:8/1:4 flexible configuration 1:4
Hard drive
6*2.5'' NVMe SSD
2*2.5'' SAS/SATA HDD
8*3.5'' HDD
2*1.8'' SATA SSD
It can be configured with the PSU2.
4*2.5'' SAS/SATA SSD/HDD
RAID RAID 0/1/10/5/50/6/60 Pluggable Raid card (occupying the extended slot of
PCIe)
PCIe expansion 4*PCIe x16 2*PCIe x16
On-board network adapter / 2*GE
Power supply 4*2200 W hot swap, 2+2 2*2000 W hot swap, 1+1
Fan 6 hot swap, 5+1 The built-in does not support hot swap. When the fan
fails, heat dissipation is affected.
Temperature
5°C to 35°C 10°C to 25°C
Beating Points
• The integrated design of the chassis does not support independent evolution of the CPUs and GPUs.
• The CPU supports only up to 145 W, which restricts support for the Scalable Processors in the future.
• Only 16 DIMMs are supported, and the memory capacity is limited.
• NVMe SSD is not supported. (Hard drives and PSU2 alternatively supported)
• The fans are built-in and require opening the chassis for maintenance.
• The supported temperature is only 10°C to 25°C, and the application is restricted.
• The internal GPU cards, PCIe expansion slots, and extended hard drives need to be connected,
which makes maintenance complicated.