7 Rectifier Management
Issue 03 (2015-01-05)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd
22
LCD Operation
Figure 7-1 Viewing rectifier operating information on the LCD
7.2 Setting Intelligent Hibernation Parameters
Principles
The operation efficiency of rectifiers is low when the load is light. If the total load of the
power system is light, certain rectifiers in the system operate with high load and others
hibernate. This mechanism improves the operation efficiency of the system and saves energy.
Rectifiers should hibernate in turn to ensure the same aging degree. If the difference between
the longest rectifier running duration and the shortest rectifier running duration exceeds the
value of exchange cycle, keep all rectifiers running for 2 hours and then hibernate certain
rectifiers.