EasyManua.ls Logo

Huck 3585 - Maintenance; General Maintenance Procedures; Daily and Weekly Checks; Sticker Information

Huck 3585
18 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
10
3585 Series Hydraulic Installation Tools (HK1080) Howmet Fastening Systems
GENERAL
the performance of the entire system. Regular inspection
and the immediate correction of minor problems will keep
schedule of “preventive” maintenance of the tool, nose
assembly, hoses, trigger and control cord, and Powerig
®
will ensure your tool’s proper operation, extend its life,
and reduce the risk of personal injury to those who
operate it.
NOTE: HUCK tools should be serviced only by personnel
who are thoroughly familiar with its operation.
Service the tool in a clean, well-lighted area. Take
special care to prevent contamination of pneumatic
from dirty work surfaces.
Have available all necessary hand tools—standard
and special.
examine them for damage and wear.
undue force.
Spare Parts Service
Kits available when servicing the tool; they include
experience dictates, should also be available.
DAILY
If a Filter-Regulator-Lubricator unit is not being used,
uncouple the air disconnects and add a few drops of
NOTE: If the tool is in continuous use, add a few
drops of oil in every 2–3 hours.
Before connecting an air hose to the tool, bleed the
air lines to clear dirt or water.
connections are secure and free of leaks; tighten or
replace if necessary.
air or hydraulic leaks; tighten, repair, or replace if
necessary.
Inspect the tool, hoses, and Powerig during operation
to detect abnormal heating, leaks, or vibration.
in mineral spirits to clear jaws
and rinse metal chips and dirt. For a more thorough
cleaning, disassemble the nose assembly. Use a dull-
pointed “pick” to remove imbedded particles from the
pull grooves of the jaws.
all parts of
TM
Jaws in mineral spirits or isopropyl alcohol only; do
not let the jaws come in contact with other solvents.
o not soak jaws; dry them immediately after
cleaning. recommends drying other parts
before re-assembling.
WEEKLY
assemblies in accordance with applicable
instructions.
and .
Inspect the
and dump valve for scored surfaces, excessive wear,
and damage; replace as necessary.
STICKERS
Stickers on the tool display safety and pressure-settings
information, and must always be legible. For more
information on sticker locations and part numbers, see
STICKER LOCATIONS.
SPARE PARTS SERVICE KITS
appropriate kit accessible. For more information, see KITS
& ACCESSORIES.
FLUID MAINTENANCE
See SPECIFICATIONS
regulations. Recycle steel, aluminum, and plastic parts in
accordance with local lawful and safe practices.
TEFLON is a registered trademark of E. I. du Pont de Nemours and
Company.
Threadmate is a registered trademark of Parker Intangibles LLC.
MAINTENANCE
CAUTION: Replace all seals, wipers,
O-rings and Back-up rings when the tool is
disassembled for any reason, and at regular
intervals, depending on severity and length
of use.
CAUTION: Do not use TEFLON
®
tape on
pipe threads. Tape can shred, resulting in
malfunctions. Apply Parker Threadmate,
Loctite 567, or Slic-tite stick to male pipe
threads per manufacturer’s instructions.