Vessel Behavioural Problems
Error Solution
When cruising, the vessel leans to starboard when
the LIST Port key is pressed or AUTO LIST is activated.
1. The servo cables are connected to the wrong
port of the RCU. Position the cables according to
the gures in the Servo Unit cable installation in
the Connection Diagram for the specic vessel.
2. Check the orientation of RCU so it corresponds
to the orientation in the control panel.
When cruising, the vessel leans to port when the LIST
Starboard key is pressed or AUTO LIST is activated.
1. The servo cables are connected to the wrong
port of the RCU. Position the cables according to
the gures in the Servo Unit cable installation in
the Connection Diagram for the specic vessel.
2. Check the orientation of RCU so it corresponds
to the orientation in the control panel.
When Coordinated Turn is activated and the
interceptors moves in and out rapidly when the vessel
changes speed.
1. The operator must even out the Coordinated
Turn curve. See Setup Manual.