Quick Checklist
1.
Ceiling fan is not installed to a solid-state wall controller. Neither leading nor
lagging edge controllers will give satisfactory performance. Wall controllers
must only be types approved for use by Hunter Pacific International.
2.
The fan, optional fan light and bracket is earthed.
3.
Fan and optional fan light are run from the same final circuit.
4.
Mounting bracket must be firmly secured to a solid structure such as a concrete
ceiling, steel structure or timber framing. If additional bracing is added it must
be firmly secured to the rafters and not left floating on the ceiling. Special
mounts, such as T-hooks, are available for certain types of installation.
5.
Fan blades are at least 2.1m (7feet) above floor level.
6.
Check the fan is operating correctly on all three speeds using the wall
controller.
7.
If light is installed. Check light switch is functioning properly.
8.
If remote control is installed. Check the fan (and light if installed) is responding
to the remote control correctly.
9.
If remote control is installed. Check where possible a separate isolation switch
has been installed for the fan.
10.
Check electrician’s details have been recorded onto the back page of the
Owner’s Operations and Warranty Manual.
Electricians make sure everything on this checklist is ticked off before you leave the installation site.
If you have trouble installing our product please refer to the trouble shooting section on the previous
page first then phone the Hunter Pacific Warranty Line on 1300 360 280 (open 9am to 5pm EST).
DO NOT
uninstall the fan and DO NOT return fan to retailer.
Electrician Installation Manual
Typhoon Ceiling Fan
15