M3858 • 1/21/21 • © 2021 Hunter Fan Company
CEILING FAN REMOTE WALL CONTROL
Model 99771
6
9
7
Installing the battery
Installing the Wall Plate
Wiring the Wall Control
Installation
Troubleshooting
Remote Function Guide
Before installation, use the pull chains to set the fan speed 
to HIGH and the light to ON. Ensure the power is OFF at the 
outlet box and wall switch location before proceeding with 
installation.
Turn Power
OFF
2
3
1
4
Remove the canopy. If uncertain how to remove it, reference the 
fan’s owner’s manual. With wiring exposed, it may be helpful 
to note existing wire connections or take a digital photo for 
reference. Remove the wire connectors that connect the wires 
from the outlet box to the fan, leaving the grounding wires 
connected. 
Turning off the power
Wiring the receiver to the fan
Installing the receiver
Removing the canopy
Choose the hanging system that most closely resembles 
the one used by your fan, and install the receiver and wire 
as directed. 
You may have installation issues if the fan is installed on an 
angled ceiling. For assistance, call 1-888-830-1326.
OR OR OR
Note: Some fans may have considerable excess lead wire. For easier canopy installation, cut the excess wire, 
leaving a minimum of 8” remaining. Re-strip the fan lead wires 1/2”. Place remaining excess wire into the ceiling 
electrical box. The bracket and fan must remain properly grounded.  
Turn the splices upward and push them carefully back through the hanger bracket into the outlet box. Spread the 
wires apart, with the grounded wires on one side of the outlet box and the ungrounded wires on the other side of 
the outlet box.
Note: If you are uncertain about wire colors or connections, please contact a qualied electrician.
Ceiling
Bracket
A
Fan Body
Cable Tie
To access the battery 
compartment, slide the 
battery door up. 
Replace the used battery 
with two AAA batteries when 
needed.
Install the shorter screws through the wall 
control plate and into the screw holes in the 
wall control.
Battery 
Door
Using the orange wire connectors, 
connect the blue wire from the receiver 
to the blue wire (or possibly black with 
white stripe wire) from the fan. Connect 
the yellow wire from the receiver to the 
black wire from the fan. 
F
R
O
M
 
R
E
C
E
I
V
E
R
black
blue
yellow
blue
F
R
O
M
 
F
A
N
5
Using the orange wire connectors, connect the black wire 
(ungrounded) from the ceiling to the black wire from the 
receiver. Connect the white wire (grounded) from the ceiling 
to both the white wire from the receiver and the white wire 
from the fan. 
AFTER ALL WIRES ARE CONNECTED and secured with wire 
connectors, re-install the canopy. 
Use the pull-chain switch on the fan to set the fan speed to 
the HIGH position before operation.
Wiring the receiver and fan to the ceiling
Turning on the power
Reference the included remote function card for 
information on how to use your wall control!
 
F
R
O
M
 
C
E
I
L
I
N
G
black
white   white (grounded)
black (ungrounded)
F
R
O
M
 
R
E
C
E
I
V
E
R
F
R
O
M
 
F
A
N
white
If you are installing multiple remote-controlled fans 
on the same circuit breaker, 
you may need to perform a few extra steps to prevent interference or faulty operation of 
your remote controls. 
 
Go to www.HunterFan.com/FAQs and click “How do I properly install multiple remote-
controlled fans?” for more information. 
ON
Turn Power
IMPORTANT
10
11
8
Installing the Wall Control
Install the longer screws through the slots 
in the wall control into the switch box screw 
holes.
8
Installing the Wall Control
Install the longer screws through the slots in 
the wall control into the switch box screw holes.
1.  Connect the grounding wire from the 
wall control to the ground control from 
the switch box using the provided wire 
nuts.
2.  Connect the “LIVE IN” from the switch 
box to the “~VAC” from the wall control 
using the provided wire nuts.
3.  Connect the “LIVE OUT” from the switch 
box to the “FAN” out from the wall control 
using the provided wire nuts.
4.  Push all wires into the switch box.
Fan On/Off
Light Dimming
Control
Dimming Mode 
On/Off
+ 
Light On/Off
Light High
Fan High
Light Low
Fan Low
Power On/Off
Long 
Press
Long 
Press
Long 
Press
Long 
Press
Long 
Press
Fan Speed 
Control
Key Press Function
+ 
Long 
Press
The remote transmitter is already paired to the receiver and ready to use. If your need to pair 
your remote, cycle power to the fan by turning power off and back on at the wall switch (or 
circuit breaker if necessary). Within three minutes, do the following:
All wiring must be in accordance with national 
and local electrical codes ANSI/NFPA 70.  If you 
are unfamiliar with wiring or in doubt, consult a 
qualied electrician.
To avoid possible electrical shock, before 
installing your fan, disconnect the power by 
turning off the circuit breakers to the outlet box 
associated with the wall switch location.
This product contains alkaline batteries: 
• Do not mix new and old batteries.
• Do not mix alkaline, carbon-zinc or 
rechargeable batteries.
• Dispose of all old batteries in 
accordance with applicable laws and 
regulations.
This device complies with part 15 of the FCC Rules. 
Operation is subject to the following two conditions: (1) 
this device may not cause harmful interference, and (2) this 
device must accept any interference received, including interference that may cause 
undesired operation. 
This device complies with RSS-210 of Industry Canada.  Operation is subject to 
the following two conditions: (1) this device may not cause interference, and (2) 
this device must accept any interference, including interference that may cause 
undesired operation of the device.
This equipment has been tested and found to comply with the limits for a Class 
B digital device, pursuant to Part 15 of the FCC Rules.  These limits are designed 
to provide reasonable protection against harmful interference in a residential 
installation.  This equipment generates, uses and can radiate radio frequency 
energy and, if not installed and used in accordance with the instructions, may cause 
harmful interference to radio communications.  However there is no guarantee that 
interference will not occur in a particular installation.  If this equipment does cause 
harmful interference to radio or television reception, which can be determined 
by turning the equipment off and on, the user is encouraged to try to correct the 
interference by one or more of the following measures:  Reorient or relocate the 
receiving antenna, Increase the separation between the equipment and receiver, 
Connect the equipment into an outlet on a circuit different from that to which the 
receiver is connected.  Consult the dealer or an experienced radio/TV technician 
for help.  Note: Any changes or modifications to the transmitter or receiver not 
expressly approved by Hunter Fan Company may void one’s authority to operate 
this remote control. Chemical burn hazard. Keep batteries away from children. 
This remote contains a lithium button cell battery. If a new or used lithium button/
coin cell battery is swallowed or enters the body, it can cause severe internal burns 
and can lead to death in as little as 2 hours. Always completely secure the battery 
compartment. If the battery compartment does not close securely, stop using the 
product, remove the batteries, and keep it away from children. If you think batteries 
might have been swallowed or placed inside any part of the body, seek immediate 
medical attention. Dispose of cells properly and keep away from children. Even 
used cells may cause injury.
This product conforms to UL Standard 1917.
WARNINGS
HUNTER FAN COMPANY CONTROL LIMITED WARRANTY
The Hunter Fan Company makes the following limited warranty to the original purchaser 
of the Control (“Control”): Your Control is warranted to be free from defects in material and 
workmanship for a period of one year from the date of sale. If the Control malfunctions or fails 
within the warranty period due to a defect in material or workmanship we will replace it free 
of charge. IF THE ORIGINAL PURCHASER CEASES TO OWN THE CONTROL, THIS WARRANTY 
AND ANY IMPLIED WARRANTY, INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTY OF 
MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, ARE VOIDED. THIS WARRANTY 
IS IN LIEU OF ALL OTHER EXPRESS WARRANTIES. THE DURATION OF ANY IMPLIED WARRANTY, 
INCLUDING, BUT NOT LIMITED TO, ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS 
FOR A PARTICULAR PURPOSE, IN RESPECT TO ANY CONTROL, IS EXPRESSLY LIMITED TO THE 
PERIOD OF THE EXPRESS WARRANTY SET FORTH ABOVE FOR SUCH CONTROL. This warranty 
excludes malfunctions or failures which were caused by repairs by persons not authorized by 
us, mishandling, improper installation, modications, or damage to the Control while in your 
possession, or unreasonable use. This warranty does not apply to batteries or to deterioration 
or damage to the product caused by the use of faulty batteries. To obtain a replacement, return 
your Control postage prepaid along with proof of purchase to Hunter Fan Company Service 
Department at 7130 Goodlett Farms Pkwy., Memphis, TN 38016. IN NO EVENT SHALL HUNTER 
FAN COMPANY BE LIABLE FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES. SOME STATES DO 
NOT ALLOW LIMITATIONS ON HOW LONG AN IMPLIED WARRANTY LASTS OR THE EXCLUSION 
OR LIMITATIONS OF INCIDENTAL OR CONSEQUENTIAL DAMAGES SO THE ABOVE LIMITATIONS 
OR EXCLUSIONS MAY NOT APPLY TO YOU. THIS WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS 
AND YOU MAY ALSO HAVE OTHER RIGHTS WHICH VARY FROM STATE TO STATE.
Read and Save These Instructions