Loading...
41951-01
6
A
3 Pin
2 Pin
Fan Motor
Light
Light
Green
Black
Black
Red
Red
White
Black
Black
White
White
Bare Copper
Ground
A14
Night Light
Night Light
Switch 1 (AC In)
Main Switch 1 (AC In)
Switch 2 (AC In)
*Option Fan & Main Light Together
*Option
A13
A16
H
A15
F
Route wires through the strain relief. For supply connection,
use wires suitable for at least 90º C (194º F).
Connect wires as shown.
Connect 4” duct and vent to the outside. Tape joints.
If ducting does not fit securely, an adapter may need
to be purchased.
Install the wiring cover plate. Make sure all
wiring connections are inside the box or under
the wiring cover plate.