MX Pool and Spa Heater Page 4
LIGHTING INSTRUCTIONS
For your safety – read before lighting
This appliance is equipped with an ignition device which automatically lights the pilot. Do not try
to light the pilot by hand.
BEFORE OPERATING smell all around the appliance area for gas. Be sure to smell next to the
floor because some gas is heavier than air and will settle on the floor.
WHAT TO DO IF YOU SMELL GAS. Do not try to light any appliance. Do not touch any
electrical switch. Do not use any telephone in your building. Immediately call your gas supplier
from a neighbor’s house.
DO NOT PLACE ARTICLES ON OR AGAINST THIS APPLIANCE
DO NOT USE OR STORE FLAMMABLE MATERIALS NEAR THIS APPLIANCE
DO NOT SPARY AEROSOLS IN THE VICINITY OF THIS APPLIANCE WHILST IT IS IN
OPERATION.
OPERATING INSTRUCTIONS
1. STOP! Read the safety information above.
2. Turn off electric power to appliance.
3. This appliance is equipped with an ignition device which automatically lights the pilot. Do
not try to light the pilot by hand.
4. Wait five minutes to clear out any gas. If you then smell gas, STOP! Refer to instructions
above.
5. Turn filtration pump on.
6. Turn on power to the heater and press the pool/spa button to select pool or spa mode.
7. Set thermostat to desired setting and press ON/OFF switch to ON.
8. The heater will ignite in around 10 seconds.
9. If the appliance will not operate, follow instructions 5 to 7 above. If the appliance still does
not ignite, call your service technician.
TO TURN GAS OFF TO APPLIANCE
1. Turn off all electrical power to the appliance.
2. Turn off gas tap in gas line prior to heater.
CHEMICAL BALANCE
It is imperative that correct chemical balance be maintained in your pool and spa water, otherwise
corrosion of your heater may occur. Corrosion of the heat exchanger voids warranty.
Your
local pool shop specialist or spa retailer can advise correct chemical balance. Your water should be
checked and maintained regularly by a pool water professional. As a guide the following
parameters may be used.
pH 7.6 to 7.8
Total Alkalinity 80 to 120 ppm
Calcium Hardness 150 to 250 ppm
Salinity 4000ppm
You should test your water chemical balance at least on a weekly basis.
Excessive sanitiser can damage your heater. Chlorine should not exceed 3 ppm and bromine
should not exceed 5 ppm. Salt chlorinators, especially when used on spa pools or indoor or
covered pools, can easily produce excessive chlorine levels which will damage the heater internals.