4 of 7
Impact
Excel
FWEG
Low / Medium Temperature
Electrical Data
Standard End Optional
Number of Fans – 4W Evaporator 1 Equipment
Amperes Watts Amperes Watts
End End End End
Evaporator Fans
120V 60Hz Standard 0.31 24
120V 50Hz Standard 0.38 27
230V 60Hz Export 0.15 24
230V 50Hz Export 0.18 27
120V 60Hz Energy Efficient 0.12 8
230V 60Hz Energy Efficient 0.06 8
Anti-sweat Heaters (on fan circuit)
120V 50/60Hz Standard 0.65 78
230V 50/60Hz Export 0.34 78
Joining Kit Anti-sweat Heaters
120V 50/60Hz Standard 0.40 48
230V 50/60Hz Export 0.21 48
Minimum Circuit Ampacity
120V 60Hz Standard 1.16 1.56
120V 50Hz Standard 1.23 1.63
230V 60Hz Export 0.69 0.90
230V 50Hz Export 0.72 0.93
120V 60Hz Energy Efficient 0.97 1.37
230V 60Hz Energy Efficient 0.60 0.81
Maximum Over Current Protection 120V 20 20
Maximum Over Current Protection 230V 15 15
Return Glass Anti-sweat Heaters
120V 50/60Hz Standard 0.13 16
230V 50/60Hz Export 0.07 16
208V Electric Defrost 6.54 1360
230V Export Electric Defrost 5.91 1360
120V Koolgas Defrost 1.33 160
Standard Lighting
None